Fabric OS Reference
1-237
Telnet Commands
1
ePortEnd
The last port to test. The test will be performed on ePortBeg to ePortEnd
inclusive. If ePortEnd is omitted then the default will be to test all ports if
ePortBeg is also omitted or to test only ePortBeg if it is specified. This operand is
optional.
setFail
Specify 1 to mark failing ports as BAD, or specify 0 to not mark failed ports as
bad. To minimize the impact on live fabrics this test normally logs errors but does
not set the port status to FAILED. This parameter is provided to force the failing
ports to be marked as BAD in the same manner as other diagnostics. In test or
qualification environments without live traffic this may be useful with large
values of nMillionFrames. This operand is optional.
DEBUG MODES
The following debug modes may be enabled with setdbg "DIAG", <level>
level Messages displayed
0 Test start, results summary only.
2 Adds test loop count (every 1 million frames).
5 Adds subtest RX messages.
9 Adds lots of little details.