1-258
Fabric OS Reference
Telnet Commands
1
When PortStatus monitoring is set to values of (0,0), port status changes are not logged to the
event log and console. Similarly, GBIC removal does not generate a message to the event log and
console if MissingGBICs is set to (0,0). By configuring these options, the user can more closely
monitor for port status and/or removal of GBICs.
Operands
None.
Example
Notice that in the following example, the only parameters modified are the number of FaultyPorts
allowed before the status of the switch changes to MARGINAL and DOWN.
See Also
switchStatusPolicyShow
switchStatusShow
switch:admin> switchStatusPolicySet
To change the overall switch status policy parameters
The current overall switch status policy parameters:
Down Marginal
----------------------------------
FaultyPorts 1 0
MissingGBICs 0 1
PowerSupplies 2 1
Temperatures 2 1
Fans 2 1
PortStatus 0 0
sgroup ISLStatus 2 1
Note that the value, 0, for a parameter, means that it is
NOT used in the calculation.
** In addition, if the range of settable values in the prompt is (0..0),
** the policy parameter is NOT applicable to the switch.
** Simply hit the Return key.
The minimum number of
FaultyPorts contributing to DOWN status: (0..8) [2]
FaultyPorts contributing to MARGINAL status: (0..8) [1]
MissingGBICs contributing to DOWN status: (0..8) [0]
MissingGBICs contributing to MARGINAL status: (0..8) [0] 1
Bad PowerSupplies contributing to DOWN status: (0..2) [2]
Bad PowerSupplies contributing to MARGINAL status: (0..2) [1]
Bad Temperatures contributing to DOWN status: (0..5) [2]
Bad Temperatures contributing to MARGINAL status: (0..5) [1]
Bad Fans contributing to DOWN status: (0..6) [2]
Bad Fans contributing to MARGINAL status: (0..6) [1]
Down PortStatus contributing to DOWN status: (0..8) [0]
Down PortStatus contributing to MARGINAL status: (0..8) [0]
Down ISLStatus contributing to DOWN status: (0..16) [2]
Down ISLStatus contributing to MARGINAL status: (0..16) [1]
Policy parameter set has been changed
... Committing configuration...done.
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...