Fabric OS Reference
1-261
Telnet Commands
1
switchStatusShow
Displays the overall status of the switch.
Synopsis
switchStatusShow
Availability
All Users
Description
Use this command to display the overall status of the switch. The overall status is calculated based
on the most severe status of all contributors:
•
Internal Switch Status
•
Faulty Ports
•
Missing GBICs
•
Power Supplies
•
Fans
•
Temperatures
•
Port Status
The overall status can be one of the following:
•
Healthy/OK - every contributor is healthy
•
Marginal/Warning - one or more components are causing a warning status
•
Down/Failed - one or more contributors have failed
If the overall status is not HEALTHY/OK, the contributing factors are listed.
Operands
None.
Example
There are two examples below. The first shows a switch with a status of MARGINAL, the second
shows the same switch after all the errors have been fixed.
See Also
switchStatusPolicyShow
switchStatusPolicySet
switch:admin> switchStatusShow
The overall switch status is Marginal/Warning
Contributing factors:
* 1 missing power supply triggered the Marginal/Warning status
* 2 bad fans, 4 good fans triggered the Marginal/Warning status
* 1 missing GBIC triggered the Marginal/Warning status
switch:admin> switchStatusShow
The overall switch status is HEALTHY/OK
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...