1-274
Fabric OS Reference
Telnet Commands
1
The test flow for each SRAM is as follows:
1.
Fill RAM with alternating FFFF 0000 pattern. (Subtest 1: turboram memory fill)
2.
For each incrementing address read FFFF 0000 pattern and write 0000 FFFF. (Subtest 2:
turbo-ram r-m-w inc 1)
3.
For each incrementing address read 0000 FFFF pattern and write FFFF 0000. (Subtest 3:
turbo-ram r-m-w inc 2)
4.
For each decrementing address read FFFF 0000 pattern and write 0000 FFFF. (Subtest 4:
turbo-ram r-m-w dec 1)
5.
For each decrementing address read 0000 FFFF pattern and write FFFF 0000. (Subtest 5:
turbo-ram r-m-w dec 2)
6.
Repeat steps 1-5 with AAAA 5555 pattern.
Operands
This command has the following operand:
passcount
Specify the number of turboRamTest passes to execute this test.
Example
To execute this test three times:
See Also
portRegTest
ramTest
centralMemoryTest
cmiTest
camTest
sramRetentionTest
switch:admin> turboRamTest 3
Running Turbo RAM Test ........ passed.