2-4
Fabric OS Reference
Error Messages
2
Diagnostic Test Failure and Recovery Actions
The table below lists what actions to perform if the switch fails any of the diagnostic tests.
Note:
If you run the portStatsShow or the diagShow command prior to running an individual
test, errors may appear as a result of the normal synchronization process. These errors
should be addressed if the number of errors found increases after running the
portStatsShow command again.
Error Message Numbers
An error number ERR#xxxx appears at the end of a diagnostic error message. The following table
matches each error number with the test that caused the error and the name of the error.
Table 2-2
Diagnostic Test Recovery Action
Failed test
Recovery Action
ramTest *
replace DRAM module or mainboard assembly
portRegTest *
replace mainboard assembly
centralMemoryTest *
replace mainboard assembly
cmiTest *
replace mainboard assembly
cmemRetentionTest
replace mainboard assembly
sramRetentionTest *
replace mainboard assembly
camTest *
replace mainboard assembly
portLoopbackTest *
replace mainboard assembly
crossPortTest
replace mainboard assembly, SFP, or fiber cable
spinSilk *
replace mainboard assembly, SFP, or fiber cable
* These tests are run during the POST (power on self test).
Table 2-3
Error Message Numbers
Error Number
Test Name
Error Name
0001
n/a
DIAG-CLEAR_ERR
0004
n/a
DIAG-POST_SKIPPED
0B15
sramRetentionTest
DIAG-REGERR
0B16
DIAG-REGERR_UNRST
0B0F
DIAG-BUS_TIMEOUT
1F25
cmemRetentionTest
DIAG-LCMRS
1F26
DIAG-LCMTO
1F27
DIAG-LCMEM
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...