Fabric OS Reference
2-9
Error Messages
2
Diagnostic Error Messages
This section provides information on the probable cause of a diagnostic error and what actions to
take.
Table 2-4
Diagnostic Error Messages
Message
Description
Probable Cause
Action
DIAG-BADINT
Err#1030, 2030
[centralMemoryTest, cmiTest]
Port received an unexpected interrupt
ASIC failure
Replace mainboard
assembly
DIAG-BUS_TIMEOUT
Err#0BoF, 4040F
[portRegTest,
sramRetentionTest]
ASIC register or ASIC SRAM did not
respond to an ASIC data access
ASIC failure
Replace mainboard
assembly
DIAG-CAMINIT
Err#223B
[camTest]
Port failed to initialize due to one of the
following reasons:
•
Switch not disabled
•
Diagnostic queue absent
•
Malloc failed
•
Chip is not present
•
Port is not in loopback mode
•
Port is not active
Software operational
setup error or main
board failure
Retry, reboot or
replace mainboard
assembly
DIAG-CAMSID
Err#223C
[camTest]
ASIC failed SID NO translation test
ASIC failure
Replace mainboard
assembly
DIAG-CLEAR_ERR
Err#0001
Port's diag error flag (OK or BAD) is
cleared
Informational Only
None required
DIAG-CMBISRF
Err#1021
[centralMemoryTest]
ASIC’s Central Memory SRAMs did not
complete the BISR within the timeout
period
ASIC failure
Replace mainboard
assembly
DIAG-CMBISRTO
Err#1020
[centralMemoryTest]
ASIC’s Central Memory SRAMs did not
complete the BISR within the timeout
period
ASIC failure
Replace mainboard
assembly
DIAG-CMERRPTN
Err#102B
[centralMemoryTest]
Error detected at the wrong port
ASIC failure
Replace mainboard
assembly
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...