2-10
Fabric OS Reference
Error Messages
2
DIAG-CMERRTYPE
Err#102A
[centralMemoryTest]
Port got the wrong CMEM error type
ASIC failure
Replace mainboard
assembly
DIAG-CMICKSUM
Err#2036
[cmiTest]
CMI message received failed bad
checksum test
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMIDATA
Err#2035
[cmiTest]
CMI data received did not match data
transmitted
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMIINVCAP
Err#2034
[cmiTest]
Unintended ASIC erroneously got CMI
capture flag
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMINOCAP
Err#2033
[cmiTest]
CMI intended receiver ASIC failed to get
CMI capture flag
ASIC or mainboard
failure
Replace mainboard
assembly
DIAG-CMISA1
Err#2032
[cmiTest]
An attempt to send a CMI message from
ASIC to ASIC failed
ASIC failure
Replace mainboard
assembly
DIAG-CMNOBUF
Err#1029
[centralMemoryTest]
Port could not get any buffer
ASIC failure
Replace mainboard
assembly
DIAG-DATA
Err#266E, 306E
[portLoopbackTest,
crossPortTest]
Payload received by port did not match
payload transmitted
mainboard, GBIC
module or fiber cable
failure
Replace mainboard
assembly, GBIC
module or fiber
cable
Table 2-4
Diagnostic Error Messages (Continued)
Message
Description
Probable Cause
Action
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...