Fabric OS Reference
2-19
Error Messages
2
Fabric Watch Error Messages
Below are six sample Fabric Watch error messages. The threshold name in the first error message is
fopportState003. The threshold label in the first error message is (FOP Port State Changes 3).
The Threshold name of the error message is equal to the class name, area name, and element index
added together to form a single character string.
For example:
class name = env,
area name = Fan,
element index = 000-002,
then the threshold name is envFan000 - envFan002
Another example is as follows:
class name = gbic,
area name = Temp,
element index = 001-00x,
then the threshold name is gbicTemp001-gbicTemp00x
0x1003f2d0 (tThad): May 22 19:20:23
Error FW-BELOW, 3, fopportState003 (FOP Port State Changes 3) is below low boundary. current value : 0
Change(s)/minute. (normal)
0x1003f2d0 (tThad): May 22 19:13:57
Error FW-ABOVE, 3, fopportCRCs007 (FOP Port Invalid CRCs 7) is above high boundary. current value : 5
Error(s)/minute. (faulty)
0x1003f2d0 (tThad): May 22 17:31:33
Error FW-ABOVE, 3, fopportSync003 (FOP Port Loss of Sync 3) is above high boundary. current value : 3
Error(s)/minute. (faulty)
0x1003f2d0 (tThad): May 22 17:31:33
Error FW-ABOVE, 3, fopportLink003 (FOP Port Link Failures 3) is above high boundary. current value : 1
Error(s)/minute. (faulty)
0x1003f2d0 (tThad): May 22 17:31:33
Error FW-CHANGED, 4, fabricFL000 (Fabric Fabric login) value has changed. current value : 23 Login(s). (info)
0x1003f2d0 (tThad): May 22 17:17:33
Error FW-ABOVE, 3, alpaPerfCRC004 (ALPA Invalid CRCs 4) is above high boundary. current value : 10
Error(s)/minute. (faulty)
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...