1
cmemRetentionTest
Test the data retention of the central memory SRAMs.
Synopsis
cmemRetentionTest [passCount]
Availability
admin
Description
Use this command to verify data retention in the central memory SRAMs in the ASIC.
Note:
This command may not be executed on an enabled switch. You must first disable the switch
using the switchDisable command.
Operands
This command has the following operand:
passCount
Specify the number of times to execute this test. The default value is 1. This
operand is optional.
Example
To run the data retention test on the central memory SRAMS:
Errors
Listed below are possible error messages if failures are detected:
DIAG-LCMRS
DIAG-LCMTO
DIAG-LCMEM
See Also
camTest
centralMemoryTest
cmiTest
crossPortTest
portLoopbackTest
ramTest
spinSilk
sramRetentionTest
switch:admin> cmemRetentionTest
Running CMEM Retention Test ... passed.