Fabric OS Reference
1-43
Telnet Commands
1
NS Pre-zoning Mode
The NS Pre-zoning Mode fields are as follows:
Pre-zoned responses Mode
Specify 0 for Standard Mode, or 1 for Pre-zoning On.
Arbitrated Loop Settings
The Arbitrated Loop Setting fields are as follows:
Send FAN frames?
Specifies that fabric address notification (FAN) frames be sent to public loop
devices to notify them of their node ID and address. When set to 1, frames are
sent; when set to 0 frames are not sent.
Always send RSCN?
Following the completion of loop initialization, a remote state change
notification (RSCN) is issued when
FL_Ports
detect the presence of new
devices or the absence of pre-existing devices. When set, a RSCN is issued upon
completion of loop initialization, regardless of the presence or absence of new or
preexisting devices.
Enable CLOSE on OPEN received?
If this is set, a CLS is returned immediately to an OPN if no buffers are available.
This is required for TachLite.
Do Not Allow AL_PA 0x00?
This option disallows ALPA values from being 0.
Initialize All Looplets?
When this is set, all looplets including the ones not in the same zone are always
re-initialized. This is required for certain RAID subsystems to work properly
during failover.
Table 1-3
Configure Command Arbitrated Loop Settings
Field
Default
Range
Send FAN frames?
1
0 or 1
Always send RSCN?
0
0 or 1
Enable CLOSE on OPEN received?
0
0 or 1
Do Not Allow AL_PA 0x00?
0
0 or 1
Initialize All Looplets?
0
0 or 1
Summary of Contents for StorageWorks 8B - FC Entry Switch
Page 1: ...reference manual version 3 0 fabric os www hp com ...
Page 14: ...xiv Fabric OS Reference ...
Page 189: ...Fabric OS Reference 1 175 Telnet Commands 1 portCfgLongDistance portCfgTrunkport portCfgSpeed ...
Page 302: ...1 288 Fabric OS Reference Telnet Commands 1 ...
Page 342: ...Index 4 Fabric OS Reference ...