Fabric OS Reference
1-69
Telnet Commands
1
fanShow
Display fan status.
Synopsis
fanShow
Availability
All users
Description
Use this command to display the current status of the switch fans.The format of the display varies
according to the switch model and number of fans. Some switch models show fan speed measured
in RPM (revolutions per minute).
Fan status is shown as:
OK
Fan is functioning correctly.
absent
Fan is not present.
below minimum Fan is present but rotating too slowly or stopped.
Operand
None.
Example
To display the status and RPMs for the fans:
See Also
psShow
tempShow
switch:admin> fanShow
Fan #1 is OK, speed is 8220 RPM
Fan #2 is OK, speed is 8400 RPM
Fan #3 is OK, speed is 8130 RPM
Fan #4 is OK, speed is 8310 RPM
Fan #5 is OK, speed is 8220 RPM
Fan #6 is OK, speed is 8430 RPM
switch:admin>