Internal Tape Drive Installation
31
DLT VS 40/80 GB Tape Drive Reference Guide
Setting the SCSI ID
Each SCSI device attached to the server that is to be the host for the DLT VS
40/80 GB tape drive must have a unique SCSI ID. Check the SCSI IDs on all other
devices attached to the selected SCSI bus, including the SCSI host adapter itself,
on the selected server and select an unused SCSI ID for the tape drive. If the drive
factory default SCSI ID 6 is not being used by another device on the same SCSI
bus, you do not need to change the SCSI ID.
Figure 7: Rear view of internal tape drive
1
68-pin SCSI connector
2
Power connector
3
SCSI ID jumpers
Note:
If the tape drive is attached to a narrow SCSI bus, only IDs 0 through 7 are valid.
1
2
3
Summary of Contents for StorageWorks DLT VS 40
Page 6: ...Contents 6 DLT VS 40 80 GB Tape Drive Reference Guide ...
Page 14: ...About this Guide 14 DLT VS 40 80 GB Tape Drive Reference Guide ...
Page 18: ...Introduction 18 DLT VS 40 80 GB Tape Drive Reference Guide ...
Page 48: ...Operating the DLT VS 40 80 Tape Drive 48 DLT VS 40 80 GB Tape Drive Reference Guide ...
Page 60: ...Regulatory Compliance Notices 60 DLT VS 40 80 GB Tape Drive Reference Guide ...
Page 66: ...Specifications 66 DLT VS 40 80 GB Tape Drive Reference Guide ...