Event Codes
159
Edge Switch 2/12 Service Manual
Table 55: Event Code 440
Message:
Embedded port hardware failed.
Severity:
Major.
Explanation:
The embedded port hardware detected a fatal CTP error.
Action:
Replace the switch.
Event Data:
Byte
0
= CTP slot position (
00
).
Byte
1
= engineering reason code
Bytes
4
through
7
= elapsed millisecond tick count.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔
✔
✔
Table 56: Event Code 442
Message:
Embedded port anomaly detected.
Severity:
Informational.
Explanation:
The switch detected a deviation in the normal operating mode or status of the
embedded port.
Action:
No action required. An additional event code is generated if this incident exceeds
an error threshold or results in a port failure.
Event Data:
Byte
0
= port number.
Byte
1
= engineering reason code.
Bytes
4
through
7
= elapsed millisecond tick count.
Bytes
8
and
9
= high-availability error callout #1.
Bytes
10
and
11
= high-availability error callout #2.
Byte
12
= detecting port.
Byte
13
= connected port.
Bytes
16
and
17
= high-availability error callout #3.
Bytes
18
and
19
= high-availability error callout #4.
Distribution:
Switch
HAFM Appliance
Host
EWS
Event
Log
System
Error
LED
Event
Log
Call
Home
Sense
Info
Link
Incident
✔