Diagnostics
45
Edge Switch 2/12 Service Manual
8
Does the EWS interface appear operational?
NO
YES
↓
Go to
step 11
.
9
A
Page cannot be found
,
Unable to locate the server
,
HTTP
404 - file not found
, or other similar message appears. The message
indicates the PC cannot communicate with the switch because:
■
The switch-to-PC Ethernet link could not be established.
■
AC power distribution in the switch failed, or AC power was disconnected.
■
The switch CTP card failed.
Continue to the next step.
10
Ensure the switch reporting the problem is connected to facility AC power.
Inspect the switch for indications of being powered on, such as:
■
At the front bezel, an illuminated PWR LED (green) or ERR LED (amber).
■
Illuminated LEDs adjacent to Fibre Channel ports.
■
Audio emanations and airflow from cooling fans.
Is a power supply or power distribution system failure indicated?
YES
NO
↓
Analysis for an Ethernet link or CTP card failure is not described in
this MAP. Go to “
” on page 32. If this is the
second time at this step, contact the next level of support. Exit MAP.
11
Inspect the power supply operational state at the EWS interface.
1. At the View panel, click the FRU Properties tab. The FRU Properties tab
displays.
2. Inspect the Status field for the power supply.