Diagnostics
48
Edge Switch 2/12 Service Manual
7
The power supply failed POSTs as indicated by FRU code 06. Replace the switch.
Exit MAP.
8
POST/IML diagnostics detected a firmware failure, as indicated by event code
411, and performed an online dump. All Fibre Channel ports reset after the failure
and devices momentarily logout, login, and resume operation.
Perform the procedure described in
Collect Maintenance Data” on page 105
Exit MAP.
MAP 0300: Loss of Web Browser PC Communication
This MAP describes fault isolation of the Ethernet communication link between a
switch and a web browser PC running the EWS interface. The failure indication is
a
Page cannot be found
,
Unable to locate the server
,
HTTP
404 - file not found
, or other similar message.
Caution:
Prior to servicing a switch, determine the Ethernet LAN
configuration. Installation of multiple switches on a public customer intranet
can complicate problem determination and fault isolation.
1
Does the EWS interface appear operational?
NO
YES
↓
The switch-to-EWS PC connection is restored and appears
operational. The cause may be an Ethernet adapter reset (on the
switch CTP card) in response to an error. The connection to the Web
browser PC terminates briefly, then recovers upon reset.
If this intermittent problem continues, perform the procedure described in
. Exit MAP.