Diagnostics
69
Edge Switch 2/12 Service Manual
■
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP M-series switch at the incorrect ELP revision level.
■
The switch is configured for operation in McDATA Fabric 1.0 mode and is
connected to a non-HP M-series switch.
Reconfigure the switch operating mode:
1. Ensure the switch is set offline. Refer to “
Set the Switch Online or Offline
2. At the EWS interface View panel, select Configure at the left side of the
panel. The Configure panel opens with the Ports page displayed.
3. Click the Switch tab, then click the Fabric Parameters tab. The Fabric
Parameters page displays.
4. Select McDATA Fabric 1.0 or Open Fabric 1.0 from the Interop Mode list
box.
— Select the McDATA Fabric 1.0 option if the switch is fabric-attached
only to other HP directors or switches that are also operating in McDATA
Fabric 1.0 mode or Homogeneous mode.
— Select the Open Fabric 1.0 option if the switch is fabric-attached to
directors or switches produced by other original equipment manufacturers
(OEMs) that are open-fabric compliant.
5. Click Activate to save the change. The message
Your changes to the
fabric parameters configuration have been
successfully activated
appears.
Did configuring the operating mode solve the problem?
NO
YES
↓
The switch appears operational. Exit MAP.
Contact the next level of support. Exit MAP.
26
A loopback (wrap) plug appears to be connected to the port and there is no
diagnostic test running. Is a loopback plug in the port receptacle?
YES
NO
↓
Contact the next level of support. Exit MAP.