Autoloader Operation
110
SSL1016 Tape Autoloader Reference Guide
Set the Cleaning Mode
To enable the Auto Clean function, you must have a slot designated for the
cleaning tape cartridge. If you or another user have already designated a slot, that
slot’s number appears next to Cleaning Cartridge Location. If a slot has not been
designated, the box is empty.
Note:
Auto Clean is not supported on Windows 2000 removable storage.
To set the cleaning tape slot:
1. On any Web Administration page, click Configurations.
2. From the drop-down list next to Cleaning Cartridge Location, select the
number of the slot in which you want to store the cleaning cartridge.
3. Click submit.
Figure 84: Cleaning Tape
If you want to set the Auto Clean option, use the following procedure. To clean the
tape drive manually, use the Move function to load and unload the cleaning tape
from the tape drive.
Summary of Contents for StorageWorks SSL1016
Page 8: ...Contents 8 SSL1016 Tape Autoloader Reference Guide ...
Page 14: ...About this Guide 14 SSL1016 Tape Autoloader Reference Guide ...
Page 22: ...Overview 22 SSL1016 Tape Autoloader Reference Guide ...
Page 60: ...Installation and Configuration 60 SSL1016 Tape Autoloader Reference Guide ...
Page 118: ...Autoloader Operation 118 SSL1016 Tape Autoloader Reference Guide ...
Page 126: ...Tape Drive Cleaning 126 SSL1016 Tape Autoloader Reference Guide ...
Page 143: ...Regulatory Compliance Notices 143 SSL1016 Tape Autoloader Reference Guide Japanese Notice ...
Page 144: ...Regulatory Compliance Notices 144 SSL1016 Tape Autoloader Reference Guide ...
Page 156: ...Upgrading or Replacing the DCA 156 SSL1016 Tape Autoloader Reference Guide ...
Page 160: ...Index 160 SSL1016 Tape Autoloader Reference Guide ...