124 Understanding Error States
Chapter 4
Slave card failed
Library slave controller card failed
power-up test.
Note:
Slave controller cards are
required in all but the lowest level of
the library.
■
Verify that a slave card is present
in all but the lowest level of the
library.
■
Verify that the cards are properly
seated.
■
Power cycle the library.
■
Contact your service
representative.
Fibre Channel
controller failed
Fibre Channel controller failed
power-up test. (Usually due to
problems on the SCSI bus, such as
an LVDS drive or terminator on an
HVDS bus, etc.)
■
Verify that proper SCSI
terminators and/or tape drives
are attached to the Fibre Channel
controller.
■
Verify that there are no bent pins
on the controller.
■
Power cycle the library.
■
Contact your service
representative.
Front Panel
Front panel not
present
Library could not detect the front
panel display.
■
Power cycle the library.
■
Contact your service
representative.
Front panel failed
Front panel display failed power-up
test.
■
Power cycle the library
■
Contact your service
representative.
Miscellaneous
Date and time not
set
The date and time is not set on the
front panel
■
Set the date and time. (See
Setting
the Date and Time
on page 108.)
Door open
One or more tape doors are open.
The library robotics will not move
until the door is closed.
■
Ensure that doors are closed.
Table 18
Partial Availability Conditions
Library Status
Cause
Solution
Summary of Contents for Surestore E Tape Library Model 2/20
Page 1: ...hp surestore tape library 2 20 4 40 6 60 8 80 and 10 100 series user s guide ...
Page 2: ......
Page 6: ...4 Updates hp surestore tape library ...
Page 12: ...10 ...
Page 116: ...114 Retrieving Library Information Chapter 3 ...
Page 182: ...180 Upgrading Firmware Chapter 5 ...
Page 222: ...220 Library Error Codes Appendix ...
Page 236: ...234 ...
Page 237: ......