Appendix
Library Error Codes 215
Appendix C
72
48H
Unable to put tape
back into slot after
power cycle.
Note the error code qualifier to help determine
appropriate testing.
74
4AH
Drive module
disconnected or has
failed.
■
Ensure that all drive modules are fully inserted
into the drive bays at the rear of the library.
■
Note the LEDs on the drive modules. See
Interpreting Library LEDs
on page 130 to
understand what the LEDs may indicate.
■
If the LED indicates failure, replace the drive
module.
75
4BH
Drive(s) fan
disconnected or
faulty.
Note the error code qualifier to help determine
appropriate testing.
76
4CH
Failed to perform an
inventory check.
Note the error code qualifier to help determine
appropriate testing.
77
4DH
Transport moved
above highest
detected level.
Run the
Test Vertical Motion
test (see
Running
Library Diagnostic Tests
on page 156).
78
4EH
Not all drives in the
library are the same
type.
Check to ensure that you have the correct type of
drive.
80
50H
Drive reports
hardware error.
■
Power cycle the library and re-try.
■
Replace the drive module if unsuccessful. See
Removing and Replacing Drive Modules
on
page 162.
81
51H
Library failed during
initialization.
Power cycle the library.
Table 46
Error Codes and Recovery Procedures
Decimal
Error
Hex
Error
Description
Recovery Method
Summary of Contents for Surestore E Tape Library Model 2/20
Page 1: ...hp surestore tape library 2 20 4 40 6 60 8 80 and 10 100 series user s guide ...
Page 2: ......
Page 6: ...4 Updates hp surestore tape library ...
Page 12: ...10 ...
Page 116: ...114 Retrieving Library Information Chapter 3 ...
Page 182: ...180 Upgrading Firmware Chapter 5 ...
Page 222: ...220 Library Error Codes Appendix ...
Page 236: ...234 ...
Page 237: ......