83
A Specifications
Introduction
This appendix provides the operating conditions (environmental requirements),
hardware specifications, physical requirements, power requirements, and video
resolutions of the HP Tower Server tc2100. The system board layout and its
connectors are also provided. See Figures A-1 and A-2.
Requirements
The following tables provide the specifications required for normal operation of
the HP Server tc2100.
Table A-1. Environmental Requirements
Parameter Conditions
Temperature
Operating
5
°
to 35
°
C (41
°
to 95
°
F)
Non-operating
-40° to +65° C (-40° to +149° F)
Humidity
Operating
20% to 80% relative humidity,
non-condensing
Non-operating
5% to 95% relative humidity,
non-condensing
Altitude
Operating
-30 to 3,000 m (~ 10,000 ft)
Non-operating
-30 to 12,000 m (~ 40,000 ft)
Thermal Output
Maximum
Operating
1066 BTU/hr
NOTE
The specifications and requirements listed above can vary if
installing a mass storage device that has more stringent
environmental limits than required for the HP Server. Ensure
the operating environment for mass storage devices are
compatible with the Server environmental requirements.