4 Troubleshooting Your Personal Workstation and Using the Setup Program
If Your Personal Workstation Has a Hardware Problem
80
English
If the Hard Disk Activity Light Does Not Work
If the hard disk activity light does not flicker when the Personal
Workstation is accessing the hard disk drive:
1
Check that the control panel connector is firmly attached to the
system board.
2
Check that the disk power and data cables are correctly connected
(refer to chapter 3).
If an Accessory Board Does Not Work
Perform the following checks:
1
Ensure the board has been firmly installed in the accessory board
slot (refer to chapter 3)
2
Ensure the board is not using memory, I/O addresses, an IRQ, or
DMA channel also being used by the Personal Workstation. Refer to
the board’s manual for details.
3
Check that the Personal Workstation has been configured correctly
in
Setup
.
4
If the problem persists, contact the accessory board vendor.