5–2
338611-001
Service and Technical Reference Guide, xw3100
Removal and Replacement Procedures
5.2 Unlocking the Smart Cover Lock
If you have locked the Smart Cover Lock use Computer Setup to unlock the lock. Refer to the
Desktop Management Guide on the Documentation Library CD for more information about the
Smart Cover Lock.
If you cannot access Computer Setup to unlock the cover you will need to remove the locking
solenoid by using the Smart Cover FailSafe Key (Spare part number 166527-001 or
166527-002). Once the solenoid has been deactivated or removed the access panel can be
removed.
The Smart Cover FailSafe Key will be needed in any of the following circumstances:
■
Power outage
■
Startup failure
■
Processor or power supply failure
■
Lost password
1. Using the
Smart Cover FailSafe Key, remove the two tamper-proof screws that secure the
Smart
Cover Lock
to the inside of the chassis.
2. Remove the workstation access panel (Section
5.5
).
To reattach the Smart Cover Lock, position the lock so that the printed circuit board it is attached
to points down when the workstation is oriented as shown. Then, secure the lock in place with the
two tamper-proof screws.
Summary of Contents for Workstation xw3100
Page 6: ...vi 338611 001 Service and Technical Reference Guide xw3100 Contents ...
Page 10: ...1 4 338611 001 Service and Technical Reference Guide xw3100 Installing the Operating System ...
Page 106: ...C 8 Service and Technical Reference Guide xw3100 POST Error Messages ...
Page 132: ...D 26 Service and Technical Reference Guide xw3100 Troubleshooting Without Diagnostics ...
Page 144: ...G 6 Service and Technical Reference Guide xw3100 Ultra ATA Drive Guidelines and Features ...