File services management
Information about the storage system in a SAN environment is provided in the HP StorageWorks SAN
Manuals page located on the HP web site at
www.hp.com/go/SDGManuals
.
Configuring data storage
HP StorageWorks X1000 and X3000 Network Storage Systems are configured only for the operating
system. The administrator must configure data storage for the storage system.
Configuring additional data storage involves creating arrays, logical disks, and volumes.
Table 3
shows the general task areas to be performed as well as the utilities needed to configure storage for
an HP Smart Array-based storage system.
Table 3 Tasks and utilities needed for storage system configuration
Storage management utility
Task
HP Array Configuration Utility or HP Automated Storage
Manager
Create disk arrays
HP Array Configuration Utility or HP Automated Storage
Manager
Create logical disks from the array space
Windows Disk Management
Verify newly created logical disks
Windows Disk Management
Create a volume on the new logical disk
•
Create disk arrays—On storage systems with configurable storage, physical disks can be arranged
as RAID arrays for fault tolerance and enhanced performance, and then segmented into logical
disks of appropriate sizes for particular storage needs. These logical disks then become the volumes
that appear as drives on the storage system.
CAUTION:
The first two logical drives are configured for the storage system operating system and should not
be altered in any manner. If the first two logical drives are altered, the system recovery process
may not function properly when using the System Recovery DVD. Do not tamper with the “DON’T
ERASE” or local C: volume. These are reserved volumes and must be maintained as they exist.
The fault tolerance level depends on the amount of disks selected when the array was created. A
minimum of two disks is required for RAID 0+1 configuration, three disks for a RAID 5 configuration,
and four disks for a RAID 6 (ADG) configuration.
•
Create logical disks from the array space—Select the desired fault tolerance, stripe size, and size
of the logical disk.
•
Verify newly created logical disks—Verify that disks matching the newly created sizes are displayed.
•
Create a volume on the new logical disk—Select a drive letter and enter a volume label, volume
size, allocation unit size, and mount point (if desired).
Storage management utilities
The storage management utilities preinstalled on the storage system include the HP Array Configuration
Utility (ACU).
File server management
28
Summary of Contents for X3800sb
Page 10: ...10 ...
Page 88: ...French laser notice German laser notice Italian laser notice Regulatory compliance notices 88 ...
Page 90: ...Bulgarian notice Czech notice Danish notice Dutch notice Regulatory compliance notices 90 ...
Page 92: ...Greek notice Hungarian notice Italian notice Latvian notice Regulatory compliance notices 92 ...
Page 95: ...Battery replacement notices Dutch battery notice X1800sb and X3800sb Network Storage Blade 95 ...
Page 96: ...French battery notice German battery notice Regulatory compliance notices 96 ...
Page 97: ...Italian battery notice Japanese battery notice X1800sb and X3800sb Network Storage Blade 97 ...
Page 98: ...Spanish battery notice Regulatory compliance notices 98 ...