NOTE:
You can specify a pool when creating THP V-VOLs if the pool has a status of
one of the following:
•
Normal status
•
Exceeded Threshold status
•
In progress of pool capacity shrinking
You can select only one pool. When
Enable
is selected in step 6, the Smart Tiers-pools
appear, and when
Disable
is selected, only the non-Smart Tiers-pools appear.
Perform the following if necessary:
•
Click
Filter
to open the menu, specify the filtering, then
Apply
.
•
Click
Options
to specify the units of pools or the number of rows to be displayed.
5.
Click
OK
.
The
Select Pool
window closes. The selected pool name appears in
Selected Pool Name
(ID)
, and the total capacity of the selected pool appears in
Selected Pool Capacity
.
8.
If you want to offset the specified LDEV capacity by boundary, change the default
Offset
boundary
from
OFF
to
ON
.
9.
In the
LDEV Capacity
text box, enter the THP V-VOL capacity to be created.
You can enter the capacity within the range of figures displayed below the text box. You can
enter the number with 2 digits after decimal point. You can change the capacity unit from the
list.
10. In the
Number of LDEVs
text box, enter the number of LDEVs to be created.
You can enter the number of LDEVs within a range of the figures displayed below the text
box.
11. In the
LDEV Name
text box, enter the THP V-VOL name.
In the
Prefix
text box, enter the alphanumeric characters, which are fixed characters of the
head of the THP V-VOL name. The characters are case-sensitive.
In the
Initial Number
text box, type the initial number following the prefix name, which can
be up to 9 digits.
You can enter up to the 32 characters including the initial number.
12. Click
Option
.
13. In the
Initial LDEV ID
field, make sure that LDEV ID is set.
To confirm the used number and unavailable number, click
View LDEV IDs
to display the
View
LDEV IDs
window.
In the table, used LDEV numbers appear in blue, unavailable numbers appear in gray, and
unused numbers appear in white. LDEV numbers that are unavailable may be already in use,
or already assigned to another emulation group (group by 32 LDEV numbers).
14. In the
Initial SSID
text box, type the 4-digit SSID of a hexadecimal number (0004 to FFFE).
To confirm the created SSID, click
View SSID
to display the
View SSID
windows.
15. From the
Cache Partition
list, select CLPR.
16. From the
MP Blade
list, select a MP blade.
Select a MP blade to be used by the LDEVs. If you assign a specific MP blade, select the ID
of the MP blade. If you can assign any MP blade, click
Auto
.
17. From the
Tiering Policy
field, select the tiering policy to be used by the LDEVs. If you assign a
specific tiering policy, select any policy. All(0) is selected by default. You can change a level
134