Loop ID
(120~125)
AL-PA
Loop ID
(90~119)
AL-PA
Loop ID
(60~89)
AL-PA
Loop ID
(30~59
AL-PA
Loop ID
(0~29)
AL-PA
-
-
118
18
88
4B
58
7A
28
B6
-
-
119
17
89
4A
59
79
29
B5
Setting the fabric switch
The Storage Administrator (Provisioning) role is required to perform this task.
When you configure your storage system, specify whether the hosts and the storage system are
connected via a fabric switch.
NOTE:
In FCoE networks,
Fabric
is fixed to
ON
. Therefore, you do not need to set
Fabric
.
1.
In the
Storage Systems
tree, click
Ports/Host Groups
.
2.
In the
Ports/Host Groups
window, select the
Ports
tab.
3.
Select the desired port.
4.
Click
Edit Ports
.
5.
Select a checkbox of
Fabric
, and select
ON
if you set the fabric switch. If you do not set the
fabric switch, select
OFF
.
6.
Click
Finish
.
7.
In the
Confirm
window, confirm the settings, in
Task Name
type a unique name for this task
or accept the default, then click
Apply
.
If
Go to tasks window for status
is checked, the
Tasks
window opens.
Fibre channel topology
The term fibre channel topology indicates how devices are connected to each other. Fibre channel
provides the following types of topology:
•
Fabric:
Uses a fabric switch to connect a large number of devices (up to 16 million) together.
Each device will have the full bandwidth of 100 MBps.
•
FC-AL (Fibre Channel-Arbitrated Loop):
A shared interface that can connect up to 126 devices
(AL-ports) together. The full-duplex data transfer rate of 100-MBps bandwidth is shared among
the devices connected to each other.
•
Point-to-point:
The simplest fibre topology connects two devices directly together.
When configuring your storage system, use the LUN Manager window to specify whether the hosts
and the storage system are connected using a fabric switch (see
“Example of FC-AL and point-to-point
).
If a fabric switch is used, specify FC-AL or point-to-point in the LUN Manager window. FC-AL is
the default. If a fabric switch is used, consult the documentation for the fabric switch to learn whether
FC-AL or point-to-point should be used. Some fabric switches require you to specify point-to-point
to get the system running.
If no fabric switch is used, specify FC-AL.
In FCoE networks,
Connection Type
is fixed to
P-to-P
. Therefore, you do not need to set
Connection
Type
.
170
Managing logical volumes