the collection of monitoring information and tier relocation operations are started again. These
operations are then performed at 1-hour intervals.
Figure 7 Collection of monitoring data to tier relocation workflow in auto execution mode
In auto execution mode, the collection of monitoring data and tier relocation operations are
performed in parallel in the next cycle. Data from these parallel processes are stored in two separate
fields.
•
Data while monitoring is in progress in the next cycle.
•
Fixed monitoring information used in the tier relocation.
Manual execution mode
You can start and stop performance monitoring and tier relocation at any time. You should keep
the duration of performance monitoring to less than 7 days (168 hours). If performance monitoring
exceeds 7 days, then monitoring stops automatically.
Manual execution mode starts and ends monitoring and relocation at the time the command is
issued. You can use scripts, which provide flexibility to control monitoring and relocation tasks
based on a schedule for each day of the week.
In manual execution mode, the next monitoring cycle can be started with the collection of monitoring
data and tier relocation operations performed in parallel. Data from these parallel processes are
stored in two separate fields.
•
Data while monitoring is in progress in the next cycle.
•
Fixed monitoring information used in the tier relocation.
Smart Tiers
79