To begin diagnostics testing:
1.
Select the
Test
tab.
2.
Select
Type of Test
to perform, select
Test Mode
, and then select either
Interactive
or
Unattended
.
3.
Choose how you want the test to be executed, either
Number of Loops
or
Total Test Time
.
●
When choosing to run the test over a specified number of loops, enter the number of loops to
perform.
●
If you want to run the diagnostic test for a specified time period, enter the amount of time in
minutes.
4.
To start the test, select
Begin Testing
in the lower right corner of the display.
While tests are performed, you can monitor the progress by viewing the Status tab. Any errors that are
detected are summarized in the Error Log. Select
Save
to save the report to a diskette or a USB key
drive (if attached).
If the diagnostics utility detects an error during a test, the user can mouse over the failed text in the
Status tab to display additional information about the type of error and the error code.
To view all test failure information, select
Error Log.
To view the status of all testing that has been
performed, select the
Log
tab.
Status tab
The Status tab displays the status of the selected tests. The type of test executed (for example, Quick,
Complete, or Custom) is displayed. The main progress bar displays the percentage of completion of the
current set of tests. While testing is in progress, the Cancel Testing button is displayed. Select this to
cancel the test.
After testing is complete, the Cancel Testing button is replaced with the Select New Tests and Retest
buttons. Select New Tests enables you to go back to the previous test selection page to select a new
set of tests. The Retest button retests the last set of tests executed. This enables you to rerun a set of
tests without having to go back to the test selection page.
The Status page also shows:
●
Devices being tested
●
Tests currently running
●
Overall test time
●
Individual test times
●
Condition status of each test
Log tab
The Log tab consists of the following views.
Test Log
—Displays all tests that have been executed, number of times a test was executed, the number
of times a test failed, and the time it took to complete the test. The Clear Test Log button clears the
contents of the Test Log.
Error Log
—Displays the tests that have failed during diagnostic testing. Besides displaying the device
and test, this section might also include error details. The description section describes the error that
the diagnostic test found. The Recommended Repair will give a recommended action that should be
128 Chapter 5 System diagnostics and troubleshooting
ENWW
Summary of Contents for Xw6600 - Workstation - 2 GB RAM
Page 1: ...HP xw6600 Workstation Service and Technical Reference Guide ...
Page 10: ...x ENWW ...
Page 114: ...104 Chapter 4 Removal and replacement procedures ENWW ...
Page 154: ...144 Chapter 7 Configuring password security and resetting CMOS ENWW ...
Page 166: ...156 Appendix A Appendix A Connector pins ENWW ...