Control panel message
Description
Recommended action
00B-MEBx Module did not checksum correctly
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
00C-PMM Deallocation Error during MEBx
Cleanup
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
00D-Setup Error during MEBx Execution
MEBx selection or exit resulted in a setup
failure.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory configuration was recently
changed, unplug the power cord, restore
the original memory configuration, and
reboot the computer.
4.
If the error persists, replace the system
board.
00E-Inventory Error during MEBx Execution
BIOS information passed to the MEBx resulted
in a failure.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
00F-Interface Error during MEBx Execution
MEBx operation experienced a hardware error
during communication with the ME.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
100-Front Audio Not Connected
Front audio cable has been detached or
unseated from system board.
Reconnect or replace front audio cable.
2E1-MemorySize Error
Memory amount has changed since the last
boot (memory added or removed).
The system memory size is different from the
last startup. The most common reason is the
removal of memory from the system board.
Press the
F1
key to save the memory changes.
If this message persists, verify that the
memory modules are installed correctly.