The automatic measuring devices are not working
The sensor was not in the rest position at switch-on (A 10) and the
key has
been pressed
to enter the wheel geometric data with the keypad, disabling control
of the automatic sensor.
➥
Return the sensors to the correct position.
Pressing the START key and the key
(only the START key if the guard is installed)
the wheel does not spin (the machine does not start)
For machines with guard, check that it is not raised (the message "A Cr" appears).
➥
Lower the wheel guard.
For machines without guard, check that both the START key as well as the key on the side
of the machine have been pressed.
The wheel balancer provides unsteady unbalance values
The machine was jolted during the spin.
➥
Repeat the spin, taking care not to disturb the machine while measuring is in pro-
gress.
The machine does not firmly rest on the floor.
➥
Make sure that the floor support is firm
The wheel is not locked correctly.
➥
Tighten the securing ring nut correctly.
Several spins are to be performed to balance the wheel
The machine was jolted during the spin.
➥
Repeat the spin, avoiding any unnecessary strain during the acquisition procedure.
The machine does not firmly rest on the floor.
➥
Make sure that the floor support is firm.
The wheel is not locked correctly.
➥
Tighten the securing ring nut correctly.
The machine has not been calibrated correctly.
➥
Carry out the sensitivity calibration procedure.
The entered geometric data are not correct.
➥
Check that the data corresponds to the dimensions of the wheel and correct, if
necessary.
➥
Perform the width measuring sensor calibration procedure.
LED light and/or laser indicator are NOT working
➥
check if the device(s) is (are) configured correctly as shown in the paragraphs “SET
UP - LED light ” and “SET UP - Laser indicator”. If the problem persists after checking
the correct device configuration, call the technical support centre.