Component -------------Summary Description-------------- Qty
Cage Degraded or failed cage power supplies 2
Cage Degraded or failed cage AC power 1
Component -Identifier- ------------Detailed Description------------
Cage cage:1 Power supply 0 is Failed
Cage cage:1 Power supply 0's AC state is Failed
Cage cage:1 Power supply 2 is Off
cage
suggested action 2
A drive enclosure (cage) power supply or power supply fan is failed, is missing input AC power, or the
switch is turned OFF. The
showcage -d
<cageID>
and
showalert
commands provide more detail.
cli%
showcage -d cage1
Id Name LoopA Pos.A LoopB Pos.B Drives Temp RevA RevB Model FormFactor
1 cage1 0:1:1 1 1:1:1 1 8 21-23 402e 402e DCS8 SFF
-----------Cage detail info for cage1 ---------
Position: ---
Interface Board Info Card0 Card1
Firmware_status Current Current
Product_Rev 402e 402e
State(self,partner) OK,OK OK,OK
VendorId,ProductId HP,DCS8 HP,DCS8
Master_CPU Yes No
SAS_Addr 50050CC1178EA0BE 50050CC1178E6BBE
Link_Speed(DP1,DP2) 6.0Gbps,Unknown 6.0Gbps,Unknown
PS PSState ACState DCState Fan State Fan0_Speed Fan1_Speed
ps0 OK OK OK OK Low Low
ps1 Failed Failed Failed OK Low Low
-------------Drive Info-------------- --PortA-- --PortB--
Drive DeviceName State Temp(C) LoopState LoopState
0:0 5000c500720387e0 Normal 21 OK OK
1:0 5000c50072039188 Normal 21 OK OK
2:0 5000c500720387b0 Normal 21 OK OK
3:0 5000c500720395b4 Normal 21 OK OK
4:0 5000c50072036fbc Normal 21 OK OK
5:0 5000c50072039fc0 Normal 21 OK OK
6:0 5000c50072037250 Normal 22 OK OK
7:0 5000c5005737cc0c Normal 23 OK OK
cage
example 3
Component -Identifier- --------------Detailed Description----------------
Cage cage:1 Cage is in "servicing" mode (Hot-Plug LED may be illuminated)
cage
suggested action 3
When a
servicecage
operation is started, it puts the targeted cage into servicing mode, and routing I/O
through another path. When the service action is finished, the
servicecage endfc
command must be
issued to return the drive enclosure (cage) to normal status. This
checkhealth
exception is reported if
the I/O module drive enclosure (cage) is in servicing mode. If a maintenance activity is occurring on the
drive enclosure (cage), this condition can be ignored.
Troubleshooting