CAUTION:
• To ensure proper thermal control, slot-filler blanks are provided with the enclosures and must be
inserted in all unused drive bays in the enclosure. Operate the enclosure only when all drive
bays are populated with either a drive or a blank.
• If the storage system is enabled with the Data-at-Rest (DAR) encryption feature, only use
Federal Information Processing Standard (FIPS) capable encrypted drives.
• Before installing drives into enclosures, make sure that the enclosures are free of obstructions
(such as loose screws, hardware, or debris). Inspect the drives before installing them in the
enclosure to make sure that they are not damaged.
• To avoid errors when powering on the storage system, all enclosures must have at least one pair
of identical drives installed by following the guidelines for installing, allocating, and balancing
drives.
Prerequisites
Determine an installation plan for allocating and loading the drives based on the provided guidelines,
number of drives, and types of drives.
Procedure
Preparation
1.
Unpack the component and place on an ESD safe mat.
2.
Connect to the HPE 3PAR Service Processor.
Browse to either the IP address or hostname:
https://<sp_ip_address>
or
https://
<hostname>
.
3.
Log in to the HPE 3PAR Service Processor (SP).
With the
3parcust
account credentials, the Service Processor Onsite Customer Care (SPOCC)
interface displays.
4.
Initiate
Check Health
on the storage system.
a.
From the SPOCC interface main menu, click
Support
in the left navigation pane.
b.
From the
Service Processor - Support
page, under
StoreServs
, click
Health Check
in the
Action
column.
A pop-up window displays a status message while the health check runs.
When running the
Health Check
using Internet Explorer, the screen might remain blank while
information is gathered. This process could take a few minutes before displaying results. Wait for
the process to complete and do not attempt to cancel or close the browser.
c.
To review the report, click either
Details
or
View Summary
.
CAUTION:
If health issues are identified during the
Check Health
scan, resolve these issues
before continuing. Refer to the details in the
Check Health
results and contact Hewlett Packard
Enterprise Support if necessary.
5.
Obtain the current drive count.
From the SSMC interface, select
Storage Systems
>
Drive Enclosures
>
Physical Drives
.
62
Upgrade