26
undo oam timer hello
Default
The port uses the global setting.
Views
Layer 2 Ethernet port view, Layer 3 Ethernet port view
Predefined user roles
network-admin
mdc-admin
Parameters
interval
: Specifies the Ethernet OAM handshake packet transmission interval, in steps of 100 (in
milliseconds). The value range for this argument is 500 to 5000.
Usage guidelines
After the timeout timer of an Ethernet OAM connection expires, the local OAM entity ages out its
connection with the peer OAM entity, causing the OAM connection to disconnect. As a best practice
to keep the Ethernet OAM connections stable, set the connection timeout timer to be at least five
times the handshake packet transmission interval.
The configuration in port view takes effect on the specified port. For a port, the configuration in port
view takes precedence.
Examples
# Set the Ethernet OAM handshake packet transmission interval to 600 milliseconds.
<Sysname> system-view
[Sysname] interface ten-gigabitethernet 1/0/1
[Sysname-Ten-GigabitEthernet1/0/1] oam timer hello 600
Related commands
•
display
oam
configuration
•
oam global timer hello
oam timer keepalive
Use
oam timer keepalive
to configure the Ethernet OAM connection timeout timer.
Use
undo oam timer keepalive
to restore the default.
Syntax
oam timer keepalive
interval
undo oam timer keepalive
Default
The port uses the global setting.
Views
Layer 2 Ethernet port view, Layer 3 Ethernet port view
Predefined user roles
network-admin
mdc-admin