128
chassis
chassis-number
slot
slot-number
: Specifies a card on an IRF member device. The
chassis-number
argument represents the member ID of the IRF member device. The
slot-number
argument represents the slot number of the card. If you do not specify a card, the command displays
information about all PSEs in the IRF fabric. (In IRF mode.)
Usage guidelines
This command is only available for the default MDC. For more information about MDCs, see
Virtual
Technologies Configuration Guide
.
Examples
# (In standalone mode.) Display general PSE information.
<Sysname> display poe device
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
7 2 0 48 800.0 Off LSQ1GV48SD0
10 3 0 48 800.0 Off LSQ1GV48SD0
# (In IRF mode.) Display general PSE information.
<Sysname> display poe device
Chassis 1:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
4 1 0 48 800.0 Off LSQ1GV48SD0
7 1 0 48 800.0 Off LSQ1GV48SD0
Chassis 2:
PSE ID Slot No. SSlot No. PortNum MaxPower(W) State Model
43 2 0 48 800.0 Off LSQ1GV48SD0
Table 21 Command output
Field Description
Chassis 1
Information for member device 1. (In IRF mode.)
PSE ID
ID of the PSE.
Slot No.
Slot number of the PSE.
SSlot No.
Sub-slot number of the PSE.
PortNum
Number of PIs on the PSE.
MaxPower(W)
Maximum power of the PSE.
State
PSE status:
•
On
—The PSE is supplying power.
•
Off
—The PSE is not supplying power.
•
Faulty
—The PSE has failed.
Model PSE
model.
display poe interface
Use
display poe interface
to display power supplying information for PIs.
Syntax
display poe interface
[
interface-type interface-number
]