153
Views
System view
Predefined user roles
network-admin
mdc-admin
Usage guidelines
If PoE over-temperature protection is enabled, the device disables PoE on all PIs when the
temperature exceeds the upper limit or drops below the lower limit.
This command is only available for the default MDC. For more information about MDCs, see
Virtual
Technologies Configuration Guide
.
Examples
# Disable PoE over-temperature protection.
<Sysname> system-view
[Sysname] undo poe temperature-protection enable
poe update
Use
poe update
to upgrade a PSE firmware when the device is operating.
Syntax
poe update
{
full
|
refresh
}
filename
[
pse
pse-id
]
Views
System view
Predefined user roles
network-admin
mdc-admin
Parameters
full
: Upgrades the PSE firmware in full mode. You can use this mode if the firmware is unavailable,
and execution of all PoE commands fails.
refresh
: Upgrades the PSE firmware in refresh mode. You can use this mode if the firmware is
available.
filename
: Specifies the name of the upgrade file, a case-sensitive string of 1 to 64 characters. The
specified file must be in the root directory of the file system of the device.
pse
pse-id
: Specifies a PSE by its ID. If you do not specify a PSE, all PSEs are upgraded.
Usage guidelines
This command is only available for the default MDC. For more information about MDCs, see
Virtual
Technologies Configuration Guide
.
Examples
# Upgrade the firmware of PSE 7 in service.
<Sysname> system-view
[Sysname] poe update refresh 0400_001.S19 pse 7