Page
11 of 21
III. Ballast Operation
This appliance must be installed directly into a single socket surge protector before being
connected to a 240V 10A General Power Outlet (Power Point). It must be a surge protector
- Circuit Breakers and Residual Current Devices (RCDs) are not suitable substitutes as
they do not protect the unit from power surges.
To guarantee user safety, this ballast features complete control and protection functions which are caused by.
1.
UV Lamp exceeding life cycle (365 Days).
2.
UV Lamp Failure.
3.
Working beyond rated voltage and load.
This ballast is designed to work with germicidal UV lamps. Do not mistake the input/output wire to avoid ballast
failure.
•
Ensure the voltage is within the specification of the ballast.
•
Match the UV lamp with the power output of the ballast.
•
Ensure the connections (plugs) are fitted correctly. Connect (screw) the
earth wire to the lug on the bottom of ballast (power source) as shown
(picture to the right). The earth wire must be affixed securely.
WORKING CONDITIONS:
The Lamp and Ballast are working correctly when the Green LED Indicator Light shows:
Display Screen - Press the “SELECT” button (for 2 seconds) to toggle between the Lamp Life Remaining
(Days) Default Display Screen and the Total Running (Days) Ballast Operation Time:
Lamp Life Remaining (Days) Default Display Screen - By default, the display screen will
show the lamp life, which counts down from 0365 to 0 days. Once the lamp life timer reaches 0,
the ballast will alarm to remind you to change the lamp.
Total Running (Days) Ballast Operation Time - Press the switch button (for up to 2 seconds)
to display the ballast operation time, which counts up from 0 to 9999 days. After 10 seconds the
screen will return to the default display.
LAMP REPLACEMENT DUE:
End of Lamp Life/UV Lamp Replacement Alarm: Once the Lamp Life Remaining timer reaches day
0, the digital display will show “A3”, the Red LED Error light will flash and an audible alarm will sound
(beeping). This indicates that it is time to replace your UV lamp.