III.WARNING 

This appliance must be installed directly into a single socket surge protector before being 

connected to a 240V 10A General Power Outlet (Power Point). It must be a surge protector 

- Circuit Breakers and Residual Current Devices (RCDs) are not suitable substitutes as 

they do not protect the unit from power surges. 

 
Danger:
 Dangerous electrical voltage is present inside the power supply box & chamber. These instructions must be 
followed closely to prevent serious personal injury. Ensure eye protection is worn when servicing and installing this 
unit to protect from harmful UV-C Radiation. This radiation can be harmful to eyes and skin, UV lamps should only be 
used when properly installed in the irradiation chamber. The UV lamp must not be operated outside the chamber. 

 

This unit must be used only for its intended purpose as described by the manufacturer. 

 

This unit must be installed in accordance with this manual. 

 

The unit must be unplugged when not in use, before fitting or removing any parts. 

 

The unit must be electrically isolated before Maintenance, Cleaning or Lamp Replacement. 

 

The System will need to be de-pressurised before maintenance. 

 

The UV lamp is designed for continuous usage to reach full disinfection capacity. Frequently turning the 
system on/off will reduce the lamp’s effectiveness and may cause the lamp to fail. 

 

Do not attempt to use this sterilizer if it has been submerged. If this occurs, turn main power off, unplug the 
electrical connection and then retrieve the unit if safe to do so.  

 

Do not operate this unit if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or 
been damaged in any manner. 

 

Always disconnect the water supply and completely drain the water purifier if it will be subjected to 
temperatures below freezing for extended periods of time. 

Overheating: For long periods of no flow the power should be turned OFF.  If the system is used intermittently, it is 
recommended to install a Thermal Relief Valve (TRV), which can be purchased separately. Excessive build-up of 
temperature in the chamber may cause the O-ring to deform and fail, causing leakage which can blow the 
lamp/power supply causing damage or personal injury. Installing a UV system without a TRV may void warranty – 
check the Warranty details for further clarification. 

IV. Before You Purchase/Open 

The system requires specific working conditions to be met before installation, some general guidelines* are listed 
below. If these conditions are not met, the system may not be suitable for the application and may not function as 
specified.These systems are designed for use in home applications on Main Water or Tank Water. For applications 
where raw water supplies are used (E.g. Bore, Dam, Creek) please contact the manufacturer for technical assistance 
to determine if your application is suitable for these systems. 

Feed Water Conditions 

Min 

Max 

Inlet Pressure 

175 kPa 

700 kPa 

Temperature 

0.5°C 

38°C 

pH Level 

11 

TDS 

0 mg/L 

2,000 mg/L 

Iron 

0 mg/L 

0.3 mg/L 

Manganese 

0 mg/L 

0.01 mg/L 

Hardness 

0 mg/L 

200 mg/L

 

Turbidity 

0 NTU 

1 NTU 

UV Transmittance 

>75% 

Summary of Contents for HPFUV

Page 1: ... Systems 5 Installation Introduction 5 I Site Preparation 5 II Stainless Steel Enclosure 6 III System Installation Mounting 6 IV Installing Connections 6 V Filter Protection 6 VI Pressure Gauge Installation 7 VII Cartridge Installation 7 Ultraviolet System Installation 8 I Thimble Quartz Tube Installation 8 II UV Lamp Installation 10 III Ballast Operation 11 System Start Up Operation 13 I Plumber ...

Page 2: ...s turn the power off immediately before conducting maintenance or repair to the system Installation must be carried out by a qualified plumber or authorised technician The power supply should always be plugged directly into a surge protector Standard power supplies are NOT water proof and must be installed out of the elements to avoid water damage This appliance is not intended for use by persons ...

Page 3: ...er off unplug the electrical connection and then retrieve the unit if safe to do so Do not operate this unit if it has a damaged cord or plug if it is malfunctioning or if it has been dropped or been damaged in any manner Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below freezing for extended periods of time Overheating For lon...

Page 4: ...ctions 6 It is important to remember that in the event that a UV is briefly shut down for routine cleaning or during power interruptions where water could have passed through the system the aforementioned pipe disinfection procedure must be conducted again The UV system should be installed after a filter on the return line This helps ensure that the water is clear of debris and impurities that cou...

Page 5: ...rbing taste and odour molecules and can provide a slight improvement in water clarity Calcite Filter Calcite filters are usually installed on Rainwater Systems to counteract the pH of acidic rainwater which usually causes green blue staining in the water or on fixtures The calcite filter is usually installed as stage 1 as it is a back washable media vessel followed by the Big Blue components of th...

Page 6: ...teel and has two keyhole mounts at the rear of the top plate for mounting the unit Allow enough space on either side for the plumbing connections and ensure there is enough space in front of the unit to allow easy removal of the front top covers and for maintenance Also allow at least 500mm height clearance for the UV lamp installation maintenance The mounting location will require a 10A GPO withi...

Page 7: ...g removed before being installed Maintain minimal contact with the surface of the carbon filter handle by the end caps only to avoid contamination as carbon will absorb smells and oils from the skin NOTE Cartridges may be supplied already inside the housings for transport however they will still be wrapped in their original wrapping as per regulatory guidelines MAKE SURE TO REMOVE THE WRAPPERS BEF...

Page 8: ...rt the glass thimble into the chamber from the top see picture right DO NOT DROP THE THIMBLE INSIDE THE CHAMBER AS IT WILL SHATTER 3 Allow equal parts of the thimble to be exposed from each end of the chamber and slide the O Rings over each end of the glass shown below Be careful not to drop the glass at this point Once the O rings are seated this will assist in holding the glass in place It is re...

Page 9: ...tening the nuts because it is likely that the bottom nut has caused the thimble to shift off centre You will need to loosen off the bottom nut and push the glass back down before continuing with tightening If you experience issues with this please contact the distributor or manufacturer for assistance 7 When following the next commissioning steps take the time to check the chamber for leaks once i...

Page 10: ... of the pins so they will only go into the power supply one way Ensure the connection is firm and plugged in all the way 4 Lower the lamp carefully down into the thimble until the lamp makes contact with the spring as shown to the right Then gently slide wiggle the white cap over the knurled nut 5 Connect the Green Yellow earth wire to the small nut per the below and finger tighten the nut over it...

Page 11: ...tomof ballast power source as shown picture to the right The earth wire must be affixed securely WORKING CONDITIONS The Lamp and Ballast are working correctly when the Green LED Indicator Light shows Display Screen Press the SELECT button for 2 seconds to toggle between the Lamp Life Remaining Days Default Display Screen and the Total Running Days Ballast Operation Time Lamp Life Remaining Days De...

Page 12: ...the button and the timer is successfully reset ERROR FAULT CONDITIONS Whilst it is usually the lamp that requires replacement please refer to the below guidance along with the Troubleshooting section of this guide to diagnose which element requires replacement LAMP FAILURE The Lamp has failed when the Red LED Indicator Light shows and or the system is alarming Note The Lamp Life will display 0 but...

Page 13: ...stalled on the system Refer to the above diagrams of a bypass in service and bypass position If the water to the house innot going to be used for over 48 hours it is recommended to turn the system into bypass mode to avoid static pressure build up in the system The UV system should also be turned off to prevent overheating in the chamber For periods of time over 1 week the above also applies howev...

Page 14: ...h alcohol or a mild detergent Lamp replacement Every 12 Months Replace Quarts Sleeve and O Rings Every 2 years H7 90 Lamp 48W HO UV Lamp to suit H7 90 AT H7 90 Thimble 470mm x 23mm OD Quartz Domed End Thimble H7 90 OR 23mm OD O Rings Replacement Ballast H7 90 PS HPF Electronic Ballast 33W 120W with Countdown Timer V Lamp Replacement CAUTION DO not touch the Lamp with your fingers Handle by the end...

Page 15: ... drop out from threaded fitting of the chamber Flush water through chamber being careful to remove all fragments from the interior of the chamber d Carefully discard all pieces of the broken quartz sleeve 9 Follow the installation steps Thimble Quartz Tube Installation steps 1 to 7 to re install the thimble into the chamber 10 Slowing restore water supply to UV system and check for leaks 11 Follow...

Page 16: ... these gauges to seal if required remove the seals and use thread tape as directed previously 2 Install the O ring into the port and try again 3 If there are any signs of damage to the port it may need replacing with a new cap No Water Flow 1 Valve Position 2 Insufficient pressure 3 Damaged or Blocked Filter 4 Filter Wrapping 1 Check that the bypass and service valves are in the correct position E...

Page 17: ...rom the system plumbing Slimy Feeling Water 1 Activated Carbon Reaction 1 This is a common symptom with activated coconut carbon It gives the feeling of ultra softened water and can feel slimy and also cause soaps to have an increased lather making it harder to rinse off This is only temporary and does not happen with every installation Ultraviolet Sanitation System Leaking from Chamber 1 O Rings ...

Page 18: ...he electricals Due to the elevator temperature of the lamp high humidity may cause condensate to form If there are no signs of leaking check for signs of shorts or charring on the lamp connection with the ballast lastly inspect the tube to see if there are any dark patches or if the filaments are burnt out 2 Sometimes the ballasts may trigger failure alarm if the connection to the lamp is interrup...

Page 19: ...uire replacement Turn the system off check connections and turn back on to see if it fixes the alarm 2 The ballast could have a problem with the lamp failure protection and may require replacement Turn the system off check connections and turn back on to see if it fixes the alarm ...

Page 20: ...warranties and manufacturer shall in no circumstance be held liable for damages consequential or otherwise or delays caused or faulty manufacturing except as excluded by law Warranties need to be approved by HPF to ensure the product was not incorrectly used installed or claimed False and incorrect claims will be pursued at HPF s discretion including chargeable inspection and transit costs incurre...

Page 21: ...warranty claimafter 6 months from date of original invoice the discount will be 50 from the next purchase of a replacement UV lamp Pro Rata Warranty only applies for a single use within the pro rata period 12 months Pro Rata Warranty only applies to components purchased new at full list price or as part of an applicable UV system Due to a large range of factors cartridges for the filter system are...