7-10
Weak link works like security system, fixing powerplant system in
open position and in emergency situations. During powerplant
retraction the weak link id inserted into the plastic tube by an elastic
cable.
Exhaust system is retracted from fuselage contour and is fixed on
own frame.
Engine Bay Door Mechanism
Main parts:
System on mechanical lever
2-piece hinged door
The door is operating on pure mechanical principles, without any
operating elements. The main door has two pieces. This door
remains open when the engine is operating.
The engine retraction has these phases:
door open
engine out.
7.11 Fuel system
Main parts:
Fuel tank
Feed pump
Refuelling pump
Fire gauge
Tank ventilation
Fuel tank
There is one fuel tank in the fuselage of total capacity 13,5 l.
Feed fuel pump
This pump feeds the powerplant system with fuel. There’s a filter on
the suction side of the feed pump. The feed pump is connected to
the powerplant control unit (Ilec) and is regulated in order to give
right amount of power automatically.