b) Fuse
•
Only fit or replace a fuse when the device is unplugged from the mains.
•
If the lamp burns out, chances are you will need to replace the fuse as well.
•
Replace a blown fuse with a fuse of the same type and ratings.
•
For the installation, you need one 5A / 250VAC 5 x 20 mm fuse:
order code : FF5N
1)
Remove the fuse holder cap on the rear panel underneath the power connector.
2)
Remove the old fuse and replace it by the new one with the same technical specifications.
3)
Replace the fuse holder cap in the housing.
c) Mounting the Device
•
Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable norms.
•
The installation of the effect has to be built and constructed in a way that it can hold 10 times the weight for 1 hour
without any harming deformation.
•
The installation must always be secured with a secondary safety attachment, e.g. an appropriate safety cable
(
VDLSC7
or
VDLSC8
).
•
Never stand directly below the device when mounting, removing or servicing the fixture.
The operator has to make sure the safety relating and machine technical installations are approved by an expert
before taking the device into operation for the first time. These installations have to be approved by a skilled
person once a year.
•
The effect should be installed outside areas where persons may reach it, walk by or be seated.
•
Overhead mounting requires extensive experience, including amongst others calculating working load limits,
installation material being used, and periodic safety inspection of all installation material and the device. If you
lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury.
•
Before mounting make sure that the installation area can hold a minimum point load of 10 times the device’s weight.
•
When installing the device, make sure there is no highly inflammable material within a distance of min. 0.5m.
•
Adjust the desired inclination angle via the mounting bracket and fix the bracket screws tightly.
•
The electric connection may only be carried out by a qualified technician.
•
Connect the fixture to the mains with the power plug. In general, lighting effects should not be connected to
dimming packs.
•
The installation has to be approved by an expert before the device is taken into service.
5. Operating Instructions
The fixture has 8 modes of operation which will be shown on the display. Select the corresponding mode by means
of the MODE button and the UP and DOWN buttons
.
001 D
: DMX mode
N1N N
: music controlled (master mode)
N2N N
: auto program (master mode)
N3N N
: standby (master mode)
S1S S
: slave 1 (slave mode)
S2S 2
: slave 2 (slave mode)
S3S S
: slave 3 (slave mode)
S4S S
: slave 4 (slave mode)
Please remember when you change modes, you have to switch the device off and back on again.