7.
Cleaning and Maintenance
Before starting any cleaning or maintenance activities:
1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
Cleaning
Use normal glass cleaner and a soft cloth to wipe off the outside casing.
Always be sure to dry all parts completely before plugging the device back in.
Cleaning frequency depends on the environment in which the unit operates (i.e.
smoke, fog residue, dust, dew).
Do not immerse the device in any liquid.
Maintenance
All screws should be tightened and free of corrosion.
The housing, the lenses, the mounting supports and the installation location (e.g.
ceiling, suspension, trussing) should not be deformed, modified or tampered with;
e.g. do not drill extra holes in mounting supports, do not change the location of the
connections…
Mechanically moving parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a qualified
technician maintain the device.
There are no user-serviceable parts, apart from the fuse and the lamp.
Refer to an authorized dealer for service and/or spare parts.
Fuse Replacement
1.
Unplug the device's power cord from the outlet.
2.
Let the device cool down.
3.
Open the fuse holder.
4.
Replace with an identical fuse.
5.
Insert the fuse holder back in its place, replace the rear cover and reconnect
power.
8.
Technical Specifications
power supply ........................................................................ 100-240 V~, 50/60 Hz
power consumption ........................................................................................ 24 W
colour ........................................................................................................... black
light source
18 x 4 W RGBW
beam angle ..................................................................................................... 25°
dimensions .............................................................................. 296 x 220 x 322 mm
weight ........................................................................................................ 2.1 kg
power factor ................................................................................................... 0.52
max. link-out current ....................................................................................... 10 A
fuse ...................................................................................................... F1AL 250V