A qualified technician should install and service this device. 

 

Do not switch the device on immediately after it has been exposed to changes in temperature. 

Protect the device against damage by leaving it switched off until it has reached room temperature. 

 

This device is designed for professional use on stage, in discos, theatres, etc. The device should only 

be used indoors with the appropriate current and power supply (see Technical Specifications). 

 

Lighting effects are not designed for permanent operation: regular operation breaks will prolong their 

lives. 

 

There may be a particular smell when the device is activated for the first time. This is normal and 

any smell will gradually disappear. 

 

Do not connect the device to a dimming pack, even if the dimmer channel is used solely for 0% to 

100% switch. 

 

Use the original packaging if the device is to be transported. 

 

Keep this manual for future reference. 

4.

 

Features 

 

lightweight aluminium construction 

 

for 50 W / 230 V lamp 

 

with power cable with plug 

5.

 

Installation 

Lamp 

 

Only fit or replace a lamp when the device is unplugged from the mains.  

 

Let a lamp cool down before replacing it as the temperature of a lamp can reach 700°C during 

operation. 

 

When handling a halogen lamp, do not touch it with your bare hands. Use a cloth to insert or remove 

it. 

 

Do not install lamps with a higher wattage. They get hotter than this device was designed for. 

 

Do not operate the device as long as the lamp is not securely fastened or the cover still opened. 

 

Replace any deformed or damaged lamp with a lamp of the same type (see Technical Specifications). 

 

To replace the lamp: 

1.

 

Pull the extension spring and open the housing. 

2.

 

Remove the old and insert a new one. 

3.

 

Fix the socket and close the device. 

Mounting guidelines 

 

Have the device installed by a qualified person, respecting EN 60598-2-17 and all other applicable 

norms. 

 

The construction to which the device is attached should be able to support 10 times the weight of the 

device for one hour without deformation. 

 

The installation must always be secured with a secondary attachment e.g. a safety cable. 

 

Never stand directly below the device when it is being mounted, removed or serviced. 

 

Have a qualified technician check the device once a year and once before you bring it into service. 

 

Install the device in a location with few passers-by that is inaccessible to unauthorised persons. 

 

Overhead mounting requires extensive experience: calculating work load limits, determining the 

installation material to be used. Have the material and the device itself checked regularly. Do not 

attempt to install the device yourself if you lack these qualifications as improper installation may 

result in injuries. 

 

Make sure there is no flammable material within a 0.5 m radius of the device. 

 

Connect the device to the mains with the power plug. 

 

The installation has to be approved by an expert before the device is taken into service. 

6.

 

Cleaning and Maintenance 

 

Disconnect the device from the mains prior to maintenance activities. Let the device cool down. 

Summary of Contents for VLP16B/GU10

Page 1: ...FITTING ZWART OF VERCHROOMD PROJECTEUR PAR16 CULOT GU10 NOIR OU CHROM FOCO PAR16 CASQUILLO GU10 NEGRO O CROMADO PAR16 SCHEINWERFER GU10 FASSUNG SCHWARZ ODER VERCHROMT VLP16B GU10 VLP16C GU10 USER MANU...

Page 2: ...sconnect mains power when device not in use or when servicing or maintenance activities are performed Handle the power cord by the plug only This device falls under protection class I It is therefore...

Page 3: ...for Do not operate the device as long as the lamp is not securely fastened or the cover still opened Replace any deformed or damaged lamp with a lamp of the same type see Technical Specifications To r...

Page 4: ...om the lamp Contact your dealer for spare parts if necessary 7 Technical Specifications power supply 230 Vac lamp socket GU10 dimensions 90 x 185 mm lamp not incl HQ Power LHALGU1050 available body co...

Page 5: ...pilepsieaanvallen bij gevoelige personen tijdelijke blindheid flitsblindheid permanente onherroepelijke schade aan de ogen Trek de stekker uit het stopcontact voordat u het toestel reinigt of als u he...

Page 6: ...afkoelen voor u ze vervangt de bedrijfstemperatuur van een lamp ligt rond de 700 C Raak een halogeenlamp niet aan met uw blote handen Gebruik een doek om de lamp te vervangen Installeer geen lampen m...

Page 7: ...Maak het toestel geregeld schoon met een vochtige niet pluizende doek Gebruik geen alcohol of oplosmiddelen Er zijn geen door de gebruiker vervangbare onderdelen in dit toestel behalve de lamp Bestel...

Page 8: ...d pilepsie chez les personnes sujettes d aveuglement temporaire aveuglement par clair d endommagement permanent irr versible de l il Toujours d brancher l appareil s il n est pas utilis et avant le ne...

Page 9: ...her une lampe halog ne mains nues Remplacer la lampe avec un chiffon Ne pas installer des lampes avec une puissance plus lev e Les lampes deviennent plus chaudes que la temp rature maximale pr vue Ne...

Page 10: ...l usage d alcool et de solvants Il n y a aucune pi ce r parable par l utilisateur sauf l ampoule Commander des pi ces de rechange ventuelles chez votre revendeur 7 Sp cifications techniques alimentat...

Page 11: ...s Desconecte siempre el aparato de la red el ctrica si no va a usarlo durante un largo per odo de tiempo y antes de su limpieza o mantenimiento Tire siempre del enchufe para desconectar el cable de re...

Page 12: ...do dise ado No maneje el aparato si la bombilla no est fijada completamente o si la tapa sigue abierta Reemplace cada l mpara deformada o defectuosa por una l mpara del mismo tipo v ase Especificacion...

Page 13: ...nguna pieza salvo la l mpara Contacte con su distribuidor si necesita piezas de recambio 7 Especificaciones alimentaci n 230 Vac casquillo GU10 dimensiones 90 x 185 mm bombilla no incl HQ Power LHALGU...

Page 14: ...auf Blicken Sie nicht direkt in die Lichtquelle um Folgendes zu vermeiden epileptische Anf lle bei empfindlichen Menschen kurzzeitige Sehst rungen Blitze permanente und unwiderrufliche Augensch den Tr...

Page 15: ...schaltetem Ger t ein Lassen Sie eine Lampe erst abk hlen bevor Sie sie ersetzen denn eine Lampe erreicht eine Temperatur von 700 C w hrend des Betriebs Ber hren Sie die Halogenlampen nicht mit blo en...

Page 16: ...en Sorgen Sie daf r dass die Netzkabel nicht besch digt sind Lassen Sie das Ger t von einer Fachkraft installieren Verwenden Sie zur Reinigung ein feuchtes fusselfreies Tuch Verwenden Sie auf keinen F...

Page 17: ...volledig terug te betalen In dat geval krijgt u een vervangend product of terugbetaling ter waarde van 100 van de aankoopsom bij ontdekking van een gebrek tot n jaar na aankoop en levering of een ver...

Page 18: ...de transporte de y a Velleman si el aparato ya no est cubierto por la garant a Cualquier art culo que tenga que ser reparado tendr que ser devuelto a su distribuidor Velleman Devuelva el aparato con l...

Reviews: