2. Light c time control (1 to 14): The starting process is the same as pure light control. After operating for a preset period of 

time (settable from 1 to 14 hours), the load stops operation automatically. 

3. Manual mode (15): In this mode, the user can switch the load on or off by the key, no matter whether it's day or night. 

4. Debugging mode (16): In cases of 6V with light signals, the load will be shut off. In cases of 5V (varies according to the preset light 

controlled  voltage  and  system  voltage)  without  light  signals,  the  load  will  be  switched  on.  This  mode  enables  fast  check  of  the 

correctness of system installation during installation and debugging. 

5. Normal on (17): The energized load keeps in output state. 

 

LED Display 

Mode 

00 

Pure light control mode 

01-14 

Light c time control (1 to 14 hours) 

15 

Manual mode

default

 

16 

Debugging mode

 

17 

Normal on mode

 

 

 

Manually Switching On/Off Load

 

 

When the load mode is set to 15 (manual mode), short press the key (non-setting mode) in any interface to switch on or off the 
load. 

 

Note: As load start is a type of soft start, display of the load icon on the LCD screen will be delayed after the load is switched on. 

 

 

Overload and Short Circuit Recovery 

Overload and short circuit automatic recovery time: 5s at the 1

st

 time; 10s at the 2

nd

 time; 25s at the 3

rd

 time; 30s at the 4

th

 time; 30s at 

the 5

th

 time, or automatic recovery the next day. 

 
 
 
 

Load switched on 

Load switched off 

 

Short press the key 

Summary of Contents for HQST-KIT-STCS100D-10A

Page 1: ...1 HQST 100W Monocrystalline Solar Suitcase User Manual...

Page 2: ...on employed charging parameters can be automatically adjusted 7 A wide range of load working modes facilitate the product s application to different types of load 8 The product provides overcharge ove...

Page 3: ...3 Solar Panel Structure Installation Instructions and Precautions 1 Unfold panel and lock butterfly washer when tilt angle desired Tilt Stand Handle Aluminum Frame...

Page 4: ...r connection in case too much loss incurred on the lines causes the controller to misjudge 5 The controller has a common positive pole inside If grounding is needed ground the positive pole 6 It s imp...

Page 5: ...ly Five load Working Modes 1 Pure light control 0 When sunlight disappears and the light intensity drops to the starting point the controller initiates a one minute delay settable to confirm the start...

Page 6: ...ion during installation and debugging 5 Normal on 17 The energized load keeps in output state LED Display Mode 00 Pure light control mode 01 14 Light control time control 1 to 14 hours 15 Manual mode...

Page 7: ...ltage is too high The battery icon flashes slowly and there is no output The battery is over discharged and will recover after recharged adequately The load icon flashes quickly and there is no output...

Page 8: ...ver discharge recovery voltage 12 6V 2 24V Over discharge voltage 11 1V 2 24V Equalizing charging interval 30days Equalizing charging time 1H Boost charging time 2H Temperature compensation 3 0mV 2V L...

Reviews: