background image

 

Error Code List 

Code on LCD screen 

Corresponding error 

E0 

No error 

E1 

battery over-discharging 

E2 

battery overvoltage 

E4 

Load short circuit 

E5 

Overload 

E6 

Controller inner temperature over heat 

 

Common Problems and Solutions 

Symptoms 

Causes and Solutions 

LCD screen does not light up.

 

Check whether the battery is correctly connected.

 

Incomplete display or no renewal on LCD screen 

Check whether the ambient temperature is too low and whether 
the display recovers when the temperature rises. 

No charging with sunlight present 

Check  whether  the  solar  panel  is  correctly  connected,  and 
contact is good and reliable. 
Check whether the solar panel voltage falls below the battery 
voltage. 

The battery icon flashes quickly, and there is no output. 

System overvoltage. Check whether the battery voltage is too 
high. 

The battery icon flashes slowly, and there is no output. 

The battery is over-discharged, and will recover after recharged 
adequately. 

The load icon flashes quickly, and there is no output. 

The load's power exceeds the rated value or  the load is short-
circuited. After the problem is solved, long press the key or wait 
until it recovers automatically. 

Other symptoms 

Check whether wiring is sound and reliable, and system voltage 
is correctly recognized. 

 

 

 

 

Solar Panel Technical Data Sheet 

Standard Testing Conditions (STC): 1000W/m

2

, T = 25°C, AM = 1.5 

Max Power at STC 

100 W 

Open circuit voltage (Voc) 

21.6 V 

Optimum operating voltage (Vmp) 

18.0 V 

Optimum operating current (Imp) 

2x2.78 A 

Short circuit current (Isc) 

2x3.08 A 

Cell Type 

Monocrystalline 

Number of Cells 

36 per panel (3 x 12 arrangement) 

Max system voltage 

600VDC (UL) 

Max series fuse rating 

15 A 

Fire rating 

Class C 

Weight 

27.05 lbs. 

Dimensions Unfolded (l x h x w) 

39.8 x 27.2 x 1.5 in 

Dimensions Folded (l x h x w) 

19.9 x 27.2 x 2.8 in 

Summary of Contents for HQST-KIT-STCS100D-10A

Page 1: ...1 HQST 100W Monocrystalline Solar Suitcase User Manual...

Page 2: ...on employed charging parameters can be automatically adjusted 7 A wide range of load working modes facilitate the product s application to different types of load 8 The product provides overcharge ove...

Page 3: ...3 Solar Panel Structure Installation Instructions and Precautions 1 Unfold panel and lock butterfly washer when tilt angle desired Tilt Stand Handle Aluminum Frame...

Page 4: ...r connection in case too much loss incurred on the lines causes the controller to misjudge 5 The controller has a common positive pole inside If grounding is needed ground the positive pole 6 It s imp...

Page 5: ...ly Five load Working Modes 1 Pure light control 0 When sunlight disappears and the light intensity drops to the starting point the controller initiates a one minute delay settable to confirm the start...

Page 6: ...ion during installation and debugging 5 Normal on 17 The energized load keeps in output state LED Display Mode 00 Pure light control mode 01 14 Light control time control 1 to 14 hours 15 Manual mode...

Page 7: ...ltage is too high The battery icon flashes slowly and there is no output The battery is over discharged and will recover after recharged adequately The load icon flashes quickly and there is no output...

Page 8: ...ver discharge recovery voltage 12 6V 2 24V Over discharge voltage 11 1V 2 24V Equalizing charging interval 30days Equalizing charging time 1H Boost charging time 2H Temperature compensation 3 0mV 2V L...