10
−
(2) How to adjust the crimp height
(Caution) To carry out crimping operation, refer to the description of operation given in the Instruction Manual
for the main unit of the crimping machine, Model CM-105. In addition, check to be sure that the crimp
terminal is attached to the correct position.
Things to be prepared • Crimping condition list
• Crimp height measuring instrument (Point blade micrometer and the like)
1) Check the crimp height requirement for the electric cable to be crimped.
2) The terminal has two crimping position, i.e., cable core section and insulation section. Set the related crimp
heights to the required values following the steps of procedure described below.
3) Set wire disk
1
and spacer disk
2
respectively to “A,” and “W.”
(Turn the disks so that the predetermined setting positions are brought to the front.)
4) Set insulation crimp height adjusting dial
3
to “1.”
(Turn the dial so that the predetermined setting position is brought to the top.)
If you pull up insulation crimp height adjusting dial
3
, you can turn it.
(Caution) Dial
3
incorporates a spring. If you release the dial, it will automatically return to its home position.
It is necessary, however, to check that the dial has properly returned to the home position.
1
Adjusting the cable core crimp height
* Carry out crimping. Measure the cable core crimp height using a point blade micrometer to check the difference
between the required height and the measured height.
* Set the position of wire disk
1
and that of spacer disk
2
within the range of the required crimp heights using
the values given below as reference.
* For wire disk
1
, the crimp height is reduced in the order of A, B, C and D in increments of approximately 0.12
mm.
* For spacer disk
2
, the crimp height is reduced in the order of W, X, Y and Z in increments of approximately 0.03
mm.
2
Adjusting the insulation crimp height
* Carry out crimping. Measure the insulation crimp height and check the difference between the required
height and the measured height.
* Set the position of insulation crimp height adjusting dial
3
within the range of required crimp heights using
the values given below as reference.
* For insulation crimp height adjusting dial
3
, the crimp height is reduced in the order of 1, 2, 3 to 7 and 8 in
increments of approximately 0.1 mm for white numerals or approximately 0.05 mm for blue numerals.
(Caution) Once you have completed the adjustment of the positions of the all disks and dials, carry out crimping
again to be sure that each crimp height satisfies the requirements. At this moment, be sure to crimp
the electric cable and check the crimp height.
(2) 夹紧高度的调整方法
( 注意 ) 进行压接工作时,请参照压接机主机 CM-105 型的使用说明书记载的运转工作程序。另外,请一定确认压接端子
的位置是否正确地安装。
准备物品 ・压接条件表
・夹紧高度测定器具 ( 点板测微计等 )
1) 请确认压接电线的夹紧高度条件。
2) 此端子压接部位是芯线部和绝缘部 2 处。请按照以下的程序设定夹紧高度条件值。
3) 请把线圆盘
1
、衬垫圆盘
2
对准 A-W。( 正面位置是设定位置。)
4) 请把绝缘夹紧高度调整拨盘
3
对准 1 号。 ( 正上方的位置是设定位置。)
向前拉绝缘夹紧高度调整拨盘
3
,就可以转动。
( 注意 ) 拨盘
3
是弹簧式,手离开后,会自动地返回,因此请一定确认是否确实地进入档位。
1
芯线夹紧高度的调整
· 进行压接,用点板微测定计测定芯线夹紧高度,确认与夹紧高度条件值的差。
· 参考下列数值,把线圆盘
1
、衬垫圆盘
2
的位置调整导夹紧高度条件值内。
· 线圆盘
1
,请按照 A → B → C → D 的顺序调整,1 档约降低夹紧高度 0.12mm。
· 衬垫圆盘
2
,请按照 W → X → Y → Z 的顺序调整,1 档约降低夹紧高度 0.03mm。
2
绝缘夹紧高度的调整
· 进行压接,测定绝缘夹紧高度,确认与夹紧高度条件值的差。
· 参考下列数值,把绝缘夹紧高度调整拨盘
3
的位置调整到夹紧高度条件值内。
· 绝缘夹紧高度调整拨盘
3
,请按照 1 → 2 → 3,7 → 8 的顺序调整,每 1 白色数字约降低夹紧高度 0.1mm,
每 1 蓝色数字约降低夹紧高度 0.05mm。
( 注意 ) 所有的圆盘、拨盘位置调整完毕之后进行压接,请确认是否符合各夹紧高度规定。此时,请一定确认电线的压接高度。
Summary of Contents for AP105