HIROSE ELECTRIC CO.,LTD.

 

 

ETAD-H0892-00

 

6 /6 

FORM HC0011-9-2 

 

 

4.  Precautions 

Do not insert or remove the socket while electrifying. 

Excessive external force applied to connectors could cause fault or damage.   
Therefore, avoid forced insertion or removal, impacts given by falling,   
or forced pulling of cables.

     

 

Avoid insert socket by bundling the cable   
or applying stress to the socket like below picture shown. 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig8. Forbidden insertion 

May.1.2020 Copyright 2020 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for DF63 Series

Page 1: ...S 3 96C Socket DF63 P 3 96DS A Header DF63 EP 3 96C In line Plug DF63 SC F A DF63 PC F A Crimp contact COUNT DESCRIPTION OF REVISIONS DESIGNED CHECKED DATE 0 名 称 TITLE DF63 Series Mating Unmating Operation Instruction Manual APPROVED HS OKAWA 20190514 CHECKED SZ ONO 20190514 DESIGNED TO KUROMATSU 20190514 WRITTEN TO KUROMATSU 20190514 TECHNICAL SPECIFICATION ETAD H0892 00 0 1 6 FORM HC0011 9 1 HIR...

Page 2: ...In line plug 3 1 b Insertion Insert the socket till it clicks while retaining the adjusted position Then it is not needed to handle the lock portion If it is inserted the socket by pushing the lock portion it does not hear click sound Fig 3 Insertion Direction of insertion Fig2 Positioning for insertion Center position Lock portion May 1 2020 Copyright 2020 HIROSE ELECTRIC CO LTD All Rights Reserv...

Page 3: ...1 c Check fitting Make sure the socket has been firmly fit with the header or In line plug Check that the socket lock has been caught at the header lock or In line plug lock by slightly pulling a cable by hand To remove the socket refer to 3 2 Socket removal Fig 4 Prohibited insertion May 1 2020 Copyright 2020 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 4: ...ket while pressing with a finger the lock spring on the socket to unlock To avoid degraded quality do not tilt the socket for removal as shown in the figure below Fig 5 Socket removal Direction of removal Lock spring Fig6 Forbidden removal May 1 2020 Copyright 2020 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 5: ...ocket in the locked status the lock is engaged to header lock portion as below picture shown Then it can not handle the lock In this case please insert the socket once After that handle the lock portion Fig7 How to handle to avoid unable unlock status Insert direction Unable unlock Able unlock Caught in lock portion May 1 2020 Copyright 2020 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 6: ... force applied to connectors could cause fault or damage Therefore avoid forced insertion or removal impacts given by falling or forced pulling of cables Avoid insert socket by bundling the cable or applying stress to the socket like below picture shown Fig8 Forbidden insertion May 1 2020 Copyright 2020 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Reviews: