HIROSE ELECTRIC CO.,LTD.

 

ETAD-H0814-00

 

2

 

5 / 6 

FORM HC0011-9-2 

 

 

4.  Precautions for handling 

 

4.1. Packing and storage 

  To pack or store assemblies, make sure overlapped connectors will not apply extreme load to 

the lack section. 

  If load is applied to the lock section under high temperature and humidity for a long period of 

time, the lock section will be deformed which could lead poor fitting. 

 
4.2. Loading to a connector 

  To pack or store assemblies, make sure overlapped connectors will not apply extreme load to 

excessive  external  force  applied  to  connectors  could  cause  failure  or  damage.  Therefore, 
avoid forced insertion or removal, dropping impact, cable wiring (pull, twist) and such. 

  Note)  Breaking  strength  of  lock  is  approx.  50  N  when  connector  is  pulled  in  straight 

direction. Please avoid excessive force is applied to the connector. 

Note)  Retention  force  is  approx.  27  N  /  Pin.  Please  avoid  excessive  force  is  applied  to 

particular cable. 

During cable wiring inside the machine, keep sufficient cable length for slack to  avoid direct 
stress is applied to the connector. 

 
4.3. Rubber seal   

   

    If the rubber seal is damaged, the connector is deteriorated water resistant performance. 

            Therefore, do not use the connector whose rubber seal is damaged. 

 
4.4. Wiring cable 

When bundling cables, prepare a part that is straight from the end face of the connector as 
shown in the figure below. 
Do not bind near the end face of the connector because it will put a load on the terminal   
contact part and the terminal crimping part and cause contact failure and waterproof   

failure.

 

 
 
 

 

Keen bending,cable tension should be avoided 

No cable tension is applied 

Straight

 

Jun.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.

Summary of Contents for DF63W Series

Page 1: ...se Name DF63 W Compatible cables 1618 AWG16 to 18 2022 AWG20 to 22 Shape packing SCF Socket terminal reeled SC Socket terminal separate PCF Plug terminal reeled PC Plug terminal separate COUNT DESCRIPTION OF REVISIONS DESIGNED CHECKED DATE 2 3 DIS H 00014188 HT SATO SZ ONO 20220621 TITLE DF63W Series Cable Assembly Procedure APPROVED KI AKIYAMA 20150525 CHECKED HK UMEHARA 20150525 DESIGNED TO HORI...

Page 2: ...1 3 3 Insertion to crimping terminal sockets Hold the cable of a crimped terminal and insert it to each terminal hole of crimping sockets Insert the terminal in the direction of arrows below The figures show insertion to DF63W 4EP 3 96C and DF63W 4S 3 96C For insertion place the crimped terminal and crimping socket lock in the following direction Before inserting terminal After inserting terminal ...

Page 3: ...mped terminal to pass through the hole of wire seal To maintain performance reliability do not tilt crimped terminals for insertion Horizontal insertion Tilted insertion Hole of wire seal Hole of wire seal Jun 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Page 4: ...of crimped terminal To remove crimped terminals that have been inserted pull the cable using the dedicated Precision Screwdriver while pushing up the crimping socket lance Using crimping socket after repair could induce decrease of lance strength and or wire seal damage Use new socket to avoid such failures Approx over 30mm In line plug lance Socket lance Crimped terminal Lance holder In line plug...

Page 5: ... straight direction Please avoid excessive force is applied to the connector Note Retention force is approx 27 N Pin Please avoid excessive force is applied to particular cable During cable wiring inside the machine keep sufficient cable length for slack to avoid direct stress is applied to the connector 4 3 Rubber seal If the rubber seal is damaged the connector is deteriorated water resistant pe...

Page 6: ...able During cable binding keep approximately 30mm length from end of connector to binding point If the length is short it could cause loosing the contact by stress Approx over 30mm Approx over 30mm Binding Jun 1 2022 Copyright 2022 HIROSE ELECTRIC CO LTD All Rights Reserved ...

Reviews: