(2) Insert the receptacle into the housing, and install bolts.
For this step, use bolts with a pitch of 1.25mm and length 10 to 12mm.
During installation, ensure that there is no excessive stress that could tear or damage the O-rings.
The recommended dimensions for the receptacle housing panel are shown in figure 1 (below).
Roughness on the panel surface indicated by
for water sealing must be
When tightening the bolts, apply a torque of approximately 6 to 6.5N
・
m.
To prevent the bolts from loosening it is recommended to apply Locktie 243 or a similar product to
the bolt area.
Figure 1: Recommended panel dimensions [units: mm]
Bolts
Panel
(recommended panel
Thickness t=2 to 4.5mm)
Receptacle
A
Panel
Attach as the o-ring NOT biting between
panel and o-ring.
Part A sectional view
Receptacle
Receptacle