(3) Crimp the electric lines with circular terminals and attach them to the main receptacle with size bolts.
For this step, use bolts with a pitch of 1.25mm and length 12 to 15mm.
(This manual assumes a terminal thickness of t=2.5 to 3mm. Use appropriate bolt sizes for different
terminal thicknesses.
)
When tightening the bolts, apply a torque of approximately 6 to 6.5N
・
m.
To prevent the bolts from loosening it is recommended to apply Locktie 243 or a similar product to
the bolt area.
Before the bolts have been tightened the female terminal of the
receptacle will be loose and will move slightly. However, after
the bolts have been tightened if the female terminal is still loose,
ensure that the crevice is less than 3mm so that nothing can fit in
between and obstruct operation.
(4) Inserting the GT8E connector
。
Receptacle
Panel
Cable
Ring terminal
Bolt(M8)
Close-up of the receptacle body
3 mm Max
HRS mark facing up
GT8E connector (lock pin facing up)
Receptacle
Panel