15
FH67 Series
●
0.5mm Pitch, 3.57mm depth One Action Lock, Vertical connection FPC/FFC/Shield FFC connector
[Operation method]
[Cautions for PCB layout]
Depending on the routing of the mating FPC, a load may be applied to the connector, which may cause failure.
In order to prevent this, please consider the following concerning the mechanism design.
[Caution]
· When routing the FPC, please be careful that FPC is not pulled and routing is carried out with extra space.
Please check that the reinforcing film is placed vertical to the board surface. (Example 25)
· Please insure there is no load applied to the connector in the pulling, inserting or lateral direction.
A bent FPC, it could cause contact failure or damage/disconnection of FPC.
Therefore, please take some measure to fix FPC etc. (Example 26)(Example 27)
· Don't place enclosures or mounting parts that will interfere with FPC. (Example 28)
· As for the flexibility of FPC, please make adjustments with the FPC manufacturer.
· Please ensure the FPC has adequate insertion space when designing the layout so that it is not inserted diagonally.
Additionally, ensure the insertion space is not too short for FPC. Please adopt adequate parts layout and length for FPC.
· When you design the board/layout, please secure required space for operation.
Routing that passed load
on reinforcing film
Enclosure/ moutning parts
interfering with FPC
The state where a load is applied to FPC
Routing that does not put
load on reinforcing film
Reinforcing film
Reinforcing film
NG
NG
NG
(Example 27)
(Example 26)
(Example 28)
OK
(Example 25)
Sep.1.2020 Copyright 2020 HIROSE ELECTRIC CO., LTD. All Rights Reserved.