■Harness Routing
Please refrain from using the cable in a state where it is always bent from
the end of the housing.
Check the cable specifications and set the minimum bending radius (R) of the cable.
■Cable Tape Winding
When wrapping the cable with tape, wrap it with tape at least 30 mm away from the bottom of
the crimp socket neck. Please wrap at least 30mm away.
If you bundle the cables close to the root, the wires at the ends may be pulled and the cables
may come off.
5.5 Crimping Quality Standard, Harness Procedure
・GT50-28SCFA Crimping Quality Standard
(Document No.ATAD-T0925-00)
・GT50
series Harness Operation Manual
(Document No.ETAD-T0930-00)