HIROSE ELECTRIC CO.,LTD.
ETAD-T0940-00
0
24
/
48
FORM HC0011-9-2
△
CHECK POINT
MEASURE
(mm)
Cover location
A
0.3 ~ 0.8
Location of tip of the core
B
0.1 ~ 0.6
Bell-mouth
C1
0.1 ~ 0.4
C2
0.1 max
C3
0.15 max
Bend-up
D
2° max
Bend-down
E
3° max
Twist
F
±2° max
Rolling
G
±5° max
Strip length
H
4.0 ~ 4.6
Width
Wire barrel
I
1.36 max
Insulation barrel
J
1.47 max
Height of metal cut-out teeth
K
0.15 max
Cut-off tab
L
0.1 max
Difference in level on transition part
Apply only bend-up
M
0.2 max
Difference in level between wire barrel
and insulation barrel
Q
0.2 ~ 0.25
Distance between wire-crimper and
wire-anvil
R
0.15 ~ 0.31
Note 1: Refer to a Crimping condition list for the crimp height.
Note 2: There is a possibility that a terminal is involved in covering and crowded by the
crimping, but it
’s no problem on the product function.
Note 3: Please confirm that the terminal which did crimp enters a housing.
Mar.1.2022 Copyright 2022 HIROSE ELECTRIC CO., LTD. All Rights Reserved.